Initial Settings - Casio IT-9000 Series Service Manual

Hide thumbs Also See for IT-9000 Series:
Table of Contents

Advertisement

5-2. Initial Settings

[ NOTE ] When the MAIN-UNIT, WAN/GPS-MODULE, or NFC-ASSY is replaced with a new one, be
sure to perform the following settings in the order indicated by "No.".
[ NOTE ] Be sure to perform the settings before proceeding to the function test.
No.
1
Registration/Check of Product ID
2
Upgrading WAN fi rmware
3
WAN settings
4
Upgrading NFC fi rmware
5-2-1. Installing the Initial Setting Program and Data
How to install the initial setting program and data is the same as that for installing the test program
and test data.
For details, refer to "5-3-3. Installing the Test Program and Test Data".
5-2-2. Setting Procedure
1.
Registration/Check of Product ID
[ NOTE ] When replacing the MAIN-UNIT with a new one, be sure to perform the following
procedure.
[ NOTE ] To read the barcode on the back side of IT-9000, you can use a USB barcode scanner
available on the market. However, before using it, be sure that it can read the barcode
correctly.
No.
Start up "IDSET_PY011.exe"
under \\My Device\FlashDisk\
DIAG.
1
Enter the barcode serial
number (product ID) written
on the back side of IT-9000.
[ NOTE ]
Enter only the rightmost 14
2
digits of the written number.
Item
Model Type
Operation
14 digits
When replacing the MAIN-UNIT
Common
USB barcode scanner
WAN
When replacing the WAN/GPS-MODULE
WAN
When replacing the WAN/GPS-MODULE
Common
When replacing the NFC-ASSY
Display
– 23 –
IT-9000
Remarks
Test Details
Check that an product ID write
tool has been started up.

Advertisement

Table of Contents
loading