Parameter
Enable
Working Period
Record
Record Delay
Send Email
Snapshot

Configuring Heat Mapping

The heat mapping feature detects moving objects in the camera scene that can be generated
as a report based on the object's heat. The heat colors range from blue to red, with blue
representing the minimum heat value and red representing the maximum heat value. This
information can then be searched and generate reports (see
Table 6-3
Tampering Configurations
Function
Check to enable the Video Tampering function.
The video masking feature is activated during the specified period. See
Configuring the Working Period on page
You can configure up to six periods per day. Draw a circle in the table
to enable the corresponding time period. Select a date. If you do not
select a date, the current setup will be applied to today only. You can
select All to apply the working period to the whole week.
Click Save to save the changes. The system goes back to the Video
Tampering interface. Click Save to exit.
When Record is enabled, video tampering will trigger a recording.
The system will wait for the specified time before it ends recording.
Select from 10 to 300 seconds.
When this function is enabled, the system sends an email alert to you
when an alarm occurs. The email settings must be configured for this
feature to be used (see
Check to enable the system to save tampering snapshot files (still
images) while the video tampering event is activated. See
61
for information about configuring where snapshots are saved.
Figure 6-5
Heat Mapping Configuration Interface
Configuring Events and Alarms | 79
76.
SMTP (Email) on page
53).
Heat Map Reports, page
800-22756 - B - 04/2017
Path on page
80).