Figure 6-7
Alarms Input Configuration Interface
Table 6-5
Alarms Input Configurations
Parameter
Function
Enable
Check to enable the alarm function.
Use the drop-down list to select the alarm input to configure. Default is
Relay-in
Alarm1.
The alarm is activated during the specified period. See
Working Period on page
Click Setup. You can configure up to six periods per day. Draw a circle
in the table to enable the corresponding time period. Select a date. If
Working Period
you do not select a date, the current setup will be applied to today only.
You can select All to apply the working period to the whole week.
Click Save to save the changes. The system goes back to the Alarm
interface. Click Save to exit.
The system logs and records only one alarm during the anti-dither
Anti-Dither
period. Choose an anti-dither period from 0 to 100 seconds.
Use the drop-down list to select the alarm Sensor Type for normally
Sensor Type
open (NO) or normally closed (NC).
Record
When Record is enabled, the alarm input will trigger a recording.
The system will wait for the specified time before it ends recording.
Record Delay
Select from 10 to 300 seconds.
When Relay-out is enabled, the alarm input will trigger an alarm output
signal to the connected relay alarm output device. Users must connect
Relay-out
an alarm output device to the relay out connection on the camera for
this feature to function.
The system will wait for the specified time after the alarm ends before it
Alarm Delay
sends the alarm output. Select from 10 to 300 seconds.