Chapter 8
Troubleshooting
Cisco SCE8000 GBE Operational Status
Table 8-2
module reflects the current Cisco SCE8000 GBE operational status
boot is complete, the operational status can be displayed using CLI command show system
operation-status.
Table 8-2
Cisco SCE8000 GBE Operational States
Cisco SCE8000 GBE
Operational Status
Booting
Operational
Warning
Failure
OL-19897-02
lists the operational states of the Cisco SCE8000 GBE . The Status LED on the Service Control
Description
Initial state after reset
Cisco SCE8000 GBE becomes operational after completing the
following process:
Boot is completed
Power-on self-tests are completed without failure
Platform configuration is applied
Cisco SCE8000 GBE is fully operational (as above) but one of the
following occurred:
GBE Management port link is down
Internal temperature above threshold
Internal voltage not in expected range
Fan problem
Power supply problem
Insufficient space on the disk
If the condition that caused the Cisco SCE8000 GBE to be
Note
in Warning state is resolved (for example, link is up) the
Cisco SCE8000 GBE reverts to Operational state.
System is in Failure state after Boot due to one of the following
conditions:
Power-on test failure
Three abnormal reboots in less than 30 minutes
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command)
Severe system health problem, such as extensive overheating
or voltage out of correct operating range.
Depending on the cause of failure, the management
Note
interface and the platform configuration may or may not be
active/available.
(Table 8-3
Cisco SCE8000 GBE Installation and Configuration Guide
Troubleshooting Overview
and
Table
8-4). Once
Status LED State
Amber
Steady green
Flashing amber
Red