Table of Contents

Advertisement

Chapter 4
Command Reference

tempmean

To display the internal case temperature alarm mean level, use the tempmean command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Examples
The following example shows how to display the internal case temperature alarm mean level.
edfa > tempmean
29.00 (C)
Related Commands
Command
resetmeantrig
settempmean
settemptrig
temp
temptrig
78-14134-01, Release 1.0
tempmean
Modification
This command was introduced.
Description
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the internal case temperature alarm mean level.
Sets the internal case temperature alarm trigger level.
Displays the internal case temperature level.
Displays the internal case temperature alarm trigger level.
tempmean
Cisco ONS 15501 User Guide
4-53

Advertisement