Table of Contents

Advertisement

Chapter 4
Command Reference

gain

To display the measured optical signal gain, use the gain command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The value for measured optical signal gain is displayed in dB.
Examples
The following example shows how to display the measured optical signal gain.
edfa > gain
17.50 (dB)
Related Commands
Command
gainmean
gaintrig
resetmeantrig
setgainmean
setgaintrig
78-14134-01, Release 1.0
gain
Modification
This command was introduced.
Description
Displays the configured signal gain and alarm mean level.
Displays the gain alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the signal gain and alarm mean level.
Sets the gain alarm trigger level.