Outsigpwr - Cisco ONS 15501 User Manual

Table of Contents

Advertisement

outsigpwr

outsigpwr
To display the calculated output signal power, use the outsigpwr command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The value for calculated output signal power is displayed in dBm.
Examples
The following example shows how to display the calculated output signal power.
edfa > outsigpwr
-28.53 (dBm)
Related Commands
Command
outsigpwrmean
outsigpwrtrig
resetmeantrig
setoutsigpwrmean
setoutsigpwrtrig
Cisco ONS 15501 User Guide
4-26
outsigpwr
Modification
This command was introduced.
Description
Displays the output signal alarm mean level.
Displays the output signal alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.