Setoutsigpwrtrig - Cisco ONS 15501 User Manual

Table of Contents

Advertisement

setoutsigpwrtrig

setoutsigpwrtrig
To set the output signal alarm trigger level, use the setoutsigpwrtrig command.
Syntax Description
trigger
Defaults
20.00 dBm
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The output signal alarm trigger is measured in dB. The system accepts a minimum value of 0.5 dB and
a maximum value of 40 dB. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to set the output signal alarm trigger level.
edfa > setoutsigpwrtrig 18.00
Related Commands
Command
outsigpwr
outsigpwrmean
outsigpwrtrig
resetmeantrig
setoutsigpwrmean
Cisco ONS 15501 User Guide
4-42
setoutsigpwrtrig trigger
Modification
This command was introduced.
Description
Displays the calculated output signal power.
Displays the output signal alarm mean level.
Displays the output signal alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the output signal alarm mean level.
Specifies the desired output signal alarm trigger level.
Chapter 4
Command Reference
78-14134-01, Release 1.0

Advertisement