Setoutsigpwrmean - Cisco ONS 15501 User Manual

Table of Contents

Advertisement

Chapter 4
Command Reference

setoutsigpwrmean

To set the output signal alarm mean level, use the setoutsigpwrmean command.
Syntax Description
mean
Defaults
2.00 dBm
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The output signal alarm mean is measured in dBm. The system accepts a minimum value of 0 dBm and
a maximum value of 40 dBm. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to set the output signal alarm mean level.
edfa > setoutsigpwrmean 1.00
Related Commands
Command
outsigpwr
outsigpwrmean
outsigpwrtrig
resetmeantrig
setoutsigpwrtrig
78-14134-01, Release 1.0
setoutsigpwrmean mean
Modification
This command was introduced.
Description
Displays the calculated output signal power.
Displays the output signal alarm mean level.
Displays the output signal alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the output signal alarm trigger level.
Specifies the desired output signal alarm mean level.
setoutsigpwrmean
Cisco ONS 15501 User Guide
4-41