The red FAIL LED turns on or off to reflect the following conditions:
The yellow LOS LED turns on or off to reflect the following conditions:
78-14134-01, Release 1.0
On: The pump laser bias, pump laser temperature, or power supply is out of tolerance. This LED
indicates a major internal failure, such as an overtemperature condition or a failure in the pump
laser or power supply.
Off: The pump laser bias, pump laser temperature, and power supply are in the specified range.
On: Input signal level is below the loss-of-input threshold.
Off: Input signal level is above the minimum input power threshold.