outsigpwrmean

To display the output signal alarm mean level, use the outsigpwrmean command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The value for output signal alarm mean level is displayed in dBm.
Examples
The following example shows how to display the output signal alarm mean level.
edfa > outsigpwrmean
2.00 (dBm)
Related Commands
Command
outsigpwr
outsigpwrtrig
resetmeantrig
setoutsigpwrmean
setoutsigpwrtrig
78-14134-01, Release 1.0
outsigpwrmean
Modification
This command was introduced.
Description
Displays the calculated output signal power.
Displays the output signal alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the output signal alarm mean level.