Table of Contents

Advertisement

Chapter 4
Command Reference

status

To display the measured, alarm mean and alarm trigger values for input power, internal case temperature,
optical gain and output signal power, as well as the measured values for optical output power and output
attenuation, use the status command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Examples
The following example shows how to display the status of the system.
edfa > status
==================================================================
Optical Output Power
Output Signal Power
==================================================================
78-14134-01, Release 1.0
status
Modification
This command was introduced.
Input Power
Temperature
Optical Gain
Output Attenuation
measured
mean
-46.03
-28.00
-28.53
85.61
29.00
17.50
17.00
0.00
-28.53
1.00
trigger
2.00
29.00
2.00
18.00
Cisco ONS 15501 User Guide
status
4-49