Module Bus Cable Shield Connection - Bosch Rexroth IndraDrive CsDrive System with HCS01 Project Planning Manual

Hide thumbs Also See for Rexroth IndraDrive CsDrive System with HCS01:
Table of Contents

Advertisement

256/341
Bosch Rexroth AG
Cables, accessories, additional components

Module bus cable shield connection

Use shielded cables for the module bus in the following cases:
An individual module bus connection is > 0.5 m long.
All drive system module bus connections together are > 3 m long.
The HAS09.1-001 accessories contain parts for assembling shielded module
bus cables:
Heat shrink tubing (3 × 20 mm)
Self-adhesive copper tape (1 × 30 mm)
Use shielded cables of a conductor size ≥ 2 × 0.5 mm
Observe the data of connection point X47.
Assembling cables:
1. Strip cable: A = 24 mm, B = 180 mm, C = 35 mm
Fig. 8-5:
Stripping the cable
2. Remove protective foil, then wrap self-adhesive copper tape around
shield braid.
Fig. 8-6:
Copper tape
3. Put 2 heat shrink tubings on cable and shrink them.
Fig. 8-7:
Heat shrink tubing
4. Fold back shield braid over cable jacket and strip wire ends.
Fig. 8-8:
Shield braid, wire ends
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
.