234/341
Bosch Rexroth AG
Technical data of the components
Description
Three-phase mains voltage at IT
mains
1)
Three-phase mains voltage at
Corner-grounded-Delta mains
Tolerance rated input voltage U
Minimum short circuit power of the
mains for failure-free operation
Minimum inductance of mains
supply (mains phase inductance)
Assigned type of mains choke
Inrush current
Maximum allowed ON-OFF cycles
per minute
4)
Mains input continuous current at
U
and
P
(single-
LN_nenn
DC_cont
phase, without mains choke)
Mains input continuous current at
U
and P
(three-phase,
LN_nenn
DC_cont
without mains choke)
6)
Mains input continuous current at
U
and
P
(single-
LN_nenn
DC_cont
phase, with mains choke)
7)
Mains input continuous current at
U
and P
(three-phase,
LN_nenn
DC_cont
with mains choke)
8)
Nominal current AC1 for mains
contactor at nom. data
Mains
fuse
according
EN 60204-1 (single-phase, with‐
out mains choke)
Mains
fuse
according
EN 60204-1 (three-phase, without
mains choke)
Mains
fuse
according
EN 60204-1 (single-phase, with
mains choke)
Mains
fuse
according
EN 60204-1 (three-phase, with
mains choke)
Symbol
Unit
U
V
LN
U
V
LN
2)
%
LN
S
MVA
k_min
L
µH
min
3)
I
L_trans_max
A
_on
I
A
LN
5)
I
A
LN
I
A
LN
I
A
LN
to
A
to
A
to
A
to
A
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
HCS01.1E
HCS01.1E
HCS01.1E
-W0003-
-W0006-
-W0009-
_-02
_-02
_-02
110...230
110...230
± 10
0.02
0.03
0.05
See figure
1.80
2.80
5.00
0.60
1.20
2.30
4;gG
6;gG
2;gG
4;gG
HCS01.1E
HCS01.1E
-W0013-
-W0018-
_-02
_-02
0.1
0.2
40
-
1
8.30
12.80
4.50
9.60
-
-
ILN
10;gG
16;gG
6;gG
16;gG
-
-
Last modification: 2012-06-28