5-2. Cleaning

5-2-6. Tape Running System and Tape Cleaner Cleaning

w
The tape cleaner has a sharp edge. Do not touch the edge with bare hands.
Pay careful attention when cleaning the tape cleaner.
Tools
. Cleaning cloth:
3-184-527-01
. Cleaning fluid:
9-919-573-01
Procedure
1. Wipe off the surfaces of the tape cleaner using a paper (such as a sheet of paper
of this manual) to chip the magnetic powder adhered on the tape cleaner.
w
Do not touch the edge portion of the tape cleaner with bare hands.
n
Do not apply an excessive force to the tape cleaner to aviod damaging it.
2. Clean the tape-running surfaces (shaded portions in the figure) of each guide
and the tape cleaner using cleaning cloth moistened with a cleaning fluid.
3. After cleaning, clean them using a dry cleaning cloth two or three times.
Pinch roller
TG-6
TG-5
TG-0
Tape cleaner
TG-2
(Entrance guide)
5-10
Capstan
TG-1
(S-TEN)
(Threading end mode)
Tape Running System and Tape Cleaner Cleaning
TG-4
TG-3(Exit guide)
TG-7
TG-8(T-TEN)
TG-9
Slant guide
TG-10
DNW-A100/A50/A45