ERROR-13 TAPE END SENSOR TROUBLE
(TAPE END SENSOR)
Description:
Malfunction of tape end sensor was detected.
Detecting condition:
When the tape end is detected continuously for more than seven seconds.
Sub error message:
None
. Tape end sensor trouble
Possible causes:
. Tape end detection circuit (MS-50 board) trouble
. Tape end input port (IC115 on SS-63 board) trouble
. Harness disconnection
. The tape cannot move at the tape end due to troubles other than the tape
sensor.
Protecting operations:
In the REW mode, continues the operation until the tape top is detected. Stops
the tape transport and enters the rest state when the tape top is detected.
During the tape transport in reverse direction, the REW mode can be entered
only while the total tape quantity is observed.
Stops the tape transport and enters the rest state during tape transport except the
above.