Replacement Procedure - Sony Betacam SX DNW-A100 Maintenance Manual

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

6-8-1. Replacement Procedure

n
Turn off the POWER switch before starting the replacement.
(1) Remove the upper lid, board retainer (S), and TBC-24 (original) board.
(Refer to "6-1-3. Plug-in Board Pulling out/Insertion".)
(2) Disconnect the one disconnected harness (that it connected TBC-24 board and TBC-23 board) from
TBC-23 board.
(3) After inserting the extension board EX-377 to the slot for TBC-24 board, and then connect a new
TBC-24 board to the extension board.
(4) Connect the extension harness to CN1 on TBC-24 (new) board and CN1 on TBC-23 board.
(5) Clean the video heads using a cleaning tape.
(Refer to "5-2-1. Cleaning using Cleaning Tape".)
(6) Perform the electrical adjustments (Section 6-8-2).
n
Remove the extension board and extension harness in some steps of the electrical adjustment.
(7) For DNW-A100/A50/A45 only
Return the ITEM-709 and ITEM-713 of setup extend menu to previous settings after the electrical
adjustments are completed.
(8) Return the states of S1100-1 on the SS-63 board and control panels to their previous states.
(9) Turn off the power, and wait for 30 seconds.
(10) Reattach the board retainer (S) and upper lid.
(Refer to "6-1-3. Plug-in Board Pulling out/Insertion".)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
http://getMANUAL.com
6-8. TBC-24 Board Replacement
6-97