Sony Betacam SX DNW-A100 Maintenance Manual page 119

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

ERROR-92 INTERNAL INTERFACE ERROR 1
(INTERNAL I/F 1)
Description:
Abnormality was detected in the communication between SYS1 CPU (IC704 on
SS-63 board) and other CPU/MPU.
Sub error messages and Detecting conditions:
SY2: When the SYS2 CPU (IC1505 on SS-63 board) initialization at power-on
SSX: When the communication with SSX board's CPU (IC204) is in abnormal
KY:
FP:
FL:
SY2: . DIP switch (S1900 on SS-63 board) setting defect
Possible causes:
SSX: . DIP switch (S300 on SSX board) setting defect
KY:
FP:
FL:
Protecting operations:
When the sub error message is "SY2", enters the protection mode.
When it is except above, displays only this error.
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
is in abnormal state.
state.
When the communication with KY-364 board's MPU (IC104) is in
abnormal state.
When the communication with FP-91 board's MPU (IC6) is in abnormal
state.
When the communication with level meter module's CPU is in abnormal
state.
. Common RAM (IC2501 on SS-63 board) or Common RAM controller
(IC2500 on SS-63 board) trouble
. System control system SY-2 area (IC1500 series on SS-63 board)
trouble
. Dual port RAM (IC302 on SSX board) trouble
. Bus buffers (IC1403 through 1405 on SS-63 board) trouble
. Cable (between MB-648 board and KY-364 board) connection defect or
disconnection
. Interface circuit (IC1102 through 1105 on SS-63 board) trouble
. Line receiver/transceiver (IC102 on KY-364 board) trouble
. KY-364 board's MPU (IC104) trouble
. Cable (between MB-648 board and FP-91 board) connection defect or
disconnection
. MPU control interface circuit (IC1400 through 1402 on SS-63 board)
trouble
. FP-91 board's MPU (IC6) trouble
. Cable (between FP-91 board and level meter module) connection defect
or disconnection
. Level meter module trouble
3-2. Details of Error Messages
3-17

Advertisement

Table of Contents
loading

Table of Contents