3-2. Details of Error Messages
ERROR-D3
SSX DIAGNOSTIC ERROR
(SSX DIAGNOSTIC)
Description:
Abnormality is detected in the diagnostic process of the SSX board at power-on.
Sub error messages and Detecting conditions:
DIAG Data Not In(31):
When the transfer completing flag is not set to the memory store register of SSX
IC (IC800 on SSX board) during transfer the test data to SD-RAM from Diag
FIFO on the SSX board. (Failed in test data transfer.)
RxCMD Incorrect(32):
When the CMD data does not coincide with the test data which is written to Rx
CMD FIFO (IC606 on SSX board) in the reading data.
RxTC Data Incorrect(33):
When the TC data does not coincide with the test data which is written to Rx TC
FIFO (IC613 on SSX board) in the reading data.
Wr DMA Fail(34):
When command end status indicates unusual state after writing the diagnostic
data to the hard disk drives. (Failed in diagnostic data writing.)
Rd Data Incorrect(35):
When the reading data does not coincide with the diagnostic data which is
written to the hard disk drives.
Rd DMA Fail(36):
When command end status indicates unusual state after reading the diagnostec
data from the hard disk drives. (Failed in diagnostic data reading.)
HDD Data Not In(37):
When the transfer completing flag is not set to the memory store register of SSX
IC (IC800 on SSX board) during transfer the test data to SD-RAM on the SSX
board from the hard disk drives. (Failed in test data transfer.)
TxTC Data Incorrect(38):
When the reading data does not coincide with the test data which is written to Tx
TC FIFO (IC702 on SSX board).
3-24
DNW-A100/A50/A45
DNW-A100P/A50P/A45P