To limit the direction in which modulation is applied
By pressing [Plus Only], turning it on, you can limit the direction in which
modulation is applied (the direction in which the image expands) to the plus
direction only.
To set the ripple center point
1
2
82
DME Special Effect Operations
Knob
Parameter
Adjustment
1
Amp A
Ripple amplitude along periphery 0.00 to 100.00
2
Freq A
Ripple frequency along periphery 0.00 to 100.00
3
a)
Direction along periphery in
Offset A
which to offset ripple phase and
amount of movement
4
b)
Ripple direction along periphery
Speed A
and speed
a) Set when Lock is on.
b) Set when Lock is off.
• When Shape mode is selected
Knob
Parameter
Adjustment
1
Amp R
Ripple amplitude
2
Freq R
Ripple frequency
3
a)
Direction in which to offset ripple
Offset R
phase and amount of movement
4
b)
Ripple direction and speed
Speed R
5
Shape
Ripple shape
Knob
Parameter
Adjustment
1
Aspect
Ripple aspect ratio
2
Angle
Ripple angle
a) Set when Lock is on.
b) Set when Lock is off.
c) 1 (Circle): Circle
2 (Rectangle): Rectangle
3 (Star): Star
4 (Heart): Heart
Press [Position], turning it on.
Set the following parameters, depending on the selected modulation mode.
Parameter group [2/2]
Parameter group [1/2]
Parameter group [2/2]
Setting values
–8.000 to +8.000
–100.00 to +100.00
Setting values
0.00 to 100.00
0.00 to 100.00
–8.000 to +8.000
–100.00 to +100.00
c)
1 to 4
Setting values
–100.00 to +100.00
–8.000 to +8.000