Sony DVS-9000 User Manual page 418

Production switcher system
Hide thumbs Also See for DVS-9000:
Table of Contents

Advertisement

a) The range of setting values depends on the DCU port setting. (When the MKS-2700 is
connected, select 2 for the slot and a value in the range 1 to 6 for the port.)
3
Press [Port Setting].
The DCU >Serial Port Assign >Extended VTR Setting menu appears.
At the top of the status area, the relevant serial port, slot number, protocol,
serial port name, and SCU number appear. In the lower part of the status
area, the response speed settings appear.
4
Using any of the following methods, specify the command to which the
response speed setting applies.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
1
Item No
a) 1.Maximum Open Delay: maximum time required to open a file
2. Maximum Cueup Delay: maximum time required to cue up a file
3. Play After Cueup Delay: maximum delay time from the cued-up state to begin playback
4. Stop Delay: delay time from issuing the stop command until actually stopping
5
Turn the knob to set the response speed of the Extended VTR.
Knob
Parameter
2
Setting
6
Press [Set].
This confirms the setting.
7
Repeat steps 4 to 6 as required to make the settings for other items.
Adjustment
Item selection
Adjustment
Response speed setting
Setting values
a)
1 to 4
Setting values
0 to 255
417
Setup Relating to DCU

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvs-9000sf

Table of Contents