Loading Know-How Protected Data To The File System - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic information about the drive system
14.8 Know-how protection
3. Select the required drive unit in the project navigator of your STARTER project.
4. Call the shortcut menu "Drive unit know-how protection > Change password".
The "Change Password" dialog box opens.
Figure 14-18
5. Enter your old password in the uppermost text box.
6. Enter your new password in the following text box and repeat it in the lowest text box.
7. The "Copy RAM to ROM" option is active by default and ensures that the new password for
the know-how protection is permanently stored in the drive unit. If you only want to change
the password temporarily, you can deactivate this option.
8. Click "OK" to close the dialog box.
Once the password has been changed successfully, you will receive a confirmation.
14.8.4

Loading know-how protected data to the file system

Data with know-how protection can be directly loaded or saved to the file system from the drive
unit. The activated know-how protection ensures that the data cannot be forwarded to
unauthorized third parties.
The following applications are conceivable at the end user:
● Adaptations of encrypted SINAMICS data are required.
● The memory card is defective.
● The Control Unit of the drive is defective.
In these cases, the OEM can create a new encrypted subproject (for a drive object) via
STARTER. The serial number of a new memory card or a new Control Unit is saved in this
encrypted data record in advance.
Application example: Control Unit is defective
Scenario:
The Control Unit of an end user is defective. The machine manufacturer (OEM) has the end
user's STARTER project files of the machine.
816
Changing the password
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions