Time stamp mode
The mode for the time stamp can be set via parameter p3100. The following modes are
available:
Setting
p3100 = 0
p3100 = 1
p3100 = 2
Also note the following information when setting a time stamp:
Note
Time stamp settings depending on the firmware version
If a project is upgraded from firmware V4.6 to V4.7 then the time stamp settings for the old
project are retained. The times displayed for the error messages do not therefore differ from
those in the old firmware version.
If a new project is created with a firmware version > V4.7, the factory setting for the p3100 = 2
and therefore a different time basis for error messages. If the response required is the one for
versions older than V4.7 then p3100 = 0 should be set.
Note
Synchronizing time stamps
If a control system and several drive devices are connected through a bus, then the different
time stamps can be synchronized to the time stamp of the control system (= time-of-day
master). Detailed information on this is provided in the manual "SINAMICS S120 Function
Manual Communication" in the chapter "Time synchronization between the control and
converter."
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Explanation
Time stamp based on operating hours
Time stamp UTC format
Time stamp operating hours + 01.01.2000
Note: With this setting, the value in p3102 is used as the time stamp for the error mes‐
sages for a firmware version > V4.7. For firmware versions < V4.7, the time basis of
p2114 was used with the setting p3100 = 0.
8.18 System runtime / operating hours counter
Basic functions
361