Fault profile
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
8.21 Tolerant encoder monitoring
Fault description
F3x100 (Zero mark dis‐
tance error)
Interjected zero mark
Zero mark too wide
Basic functions
Remedy
Check whether the con‐
nection assignment is
correct (R interchanged
with –R)
Use zero mark tolerance
Use edge evaluation of
the zero mark