Extended Smart Mode; Smart Infeed Open-Loop Control - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Infeed
3.3 Smart Infeed
3.3.2

Extended Smart Mode

Requirement
● The Smart Mode is active (p3400.0 = 1).
Function description
The operating mode "Extended Smart Mode" represents and extension of the Smart Mode, and
facilitates a higher efficiency no-load operation and partial load operation as well as a more
rugged operating behavior.
Features
The function is characterized by the following features:
● Significantly reduced reactive power drawn in no-load operation and partial load operation.
At rated load or overload, the operating behavior is equivalent to the normal Smart Mode.
● More stable DC link voltage in no-load operation and partial load operation.
At rated load or overload, the operating behavior is equivalent to the normal Smart Mode.
● Increased degree of ruggedness with respect to brief line disturbances.
● After each POWER ON, automatic adaptation to the actual line parameters.
Restrictions
The function is not available for Smart Line Modules with 5 and 10 kW.
Activating the function
Activate the Extended Smart Mode with p3440.1 = 1.
All other adjustable parameters (p3441 and following) are appropriately preset for standard
applications, or are automatically optimized with the first operating enable (p3440.2 = 0).
3.3.3

Smart Infeed open-loop control

Description
The Smart Line Module can be controlled via the BICO interconnection, e.g. using terminals or
the fieldbus. The operating status is indicated on the operating display r0002. The missing
enable signals for operation (r0002 = 00) are mapped in parameter r0046. The EP terminals
(enable pulses) must be connected in accordance with the manual of the corresponding power
units. The drive unit must have been commissioned for the first time.
Acknowledging faults
Faults that are still present but the causes of which have been rectified can be acknowledged
using a 0/1 edge at the "1st acknowledge faults" signal (p2103).
52
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions

Advertisement

Table of Contents
loading