MMC: 824-L
DESCRIPTION:
This MMC is the translation table that defines the extension dialing plan for the
networked systems.
PROGRAMMED FIELD DESCRIPTIONS:
PP
Dial Plan Number (01-96)
DDDD
Link ID and leading digits for the extension numbers in that switch (8
characters maximum)
SZ
Number of digts in extension number (0-9)
MAX
Number of digits total (1-20) for ID number and extension number.
MB
Create mailbox for this extension range in this switch (Y/N).
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
ACTION
1. Press TRSF 824
Display shows
2. Press UP or DOWN key to select
Plan number and press RIGHT
soft key to move cursor
3. Enter LINK ID and FIRST DIGIT of
extension number using the keypad
and press RIGHT soft key to move cursor
4. Enter number of digits in the extension
number. Cursor advances to next field
5. Dial maximum number of digits. Cursor
advances to next field.
NETWORK DIAL PLAN
PP:NONE ➝ DDDD
SZ:X MAX:XX MB:XX
Used to scroll through options
Used to enter selections
Move cursor left and right
PROGRAMMING
PART 2 OCTOBER 2002
[L VERSION ONLY]
DISPLAY
01: NONE➝ ➝ ➝ ➝
SZ:0 MAX:00 MB:N
10: NONE➝ ➝ ➝ ➝ ___
SZ:0 MAX:00 MB:N
10: NONE➝ ➝ ➝ ➝ 0033
SZ:0 MAX:04 MB:N
10: NONE➝ ➝ ➝ ➝ 0033
SZ:3 MAX:04 MB:N
10: NONE➝ ➝ ➝ ➝ 0033
SZ:3 MAX:06 MB:N