TECHNICAL MANUAL
MMC: 605
DESCRIPTION:
Determines which relays will close when one of the four external page zones is
accessed.
NOTE: The system must be equipped with a MISC daughter-board to allow external
paging.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
ACTION
1. Press TRSF 605
Display shows first page zone
2. Dial page zone number (e.g., 6)
OR
Use UP or DOWN to select desired page
zone numbers and press RIGHT soft key to
move the cursor
3. Dial member number (e.g., 3)
OR
Use UP or DOWN to select member
numbers and press RIGHT soft key to move
the cursor
OR
Press LEFT soft key to return to step 2 above
4. Dial relay number via dial keypad (e.g.,
3602)
and press RIGHT soft key to return to step 2
OR
Press LEFT soft key to return to step 3 above
ASSIGN EXTERNAL PAGE ZONE
PROGRAMMING
PART 2 NOVEMBER 2001
DISPLAY
EXT. PAGE ZONE:(5)
MEMBER 1:3601
EXT. PAGE ZONE:(6)
MEMBER 1:NONE
EXT. PAGE ZONE:(6)
MEMBER 3:
EXT. PAGE ZONE:(6)
MEMBER 3:3602