TECHNICAL MANUAL
MMC: 805
DESCRIPTION:
Allows the system administrator to set the base level of the TX volume on keysets
system wide. There are eight (8) levels those are able to be controled by the VOL
UP and DOWN key on keyset. And maximum controllable levels in the system are
ten (10). Keyset station users can vary eight levels. So this MMC gives the most
flexibility to the system administrator so he can classify any desired eight(8) levels
within eleven (11).
NOTE: This MMC should not be changed from the default levels without the
assistance of the STA technical support department
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
ACTION
1. Press TRSF 805
Display shows
2. Press UP or DOWN key to make selection
(TX LEVEL CONTROL, MISC TSW GAIN
or TSW GAIN CONTROL)
After selection is made, press RIGHT soft key
to move cursor to volume level or tsw connect
type option
3.a. Press RIGHT soft key to go to the volume level
OR
Use UP or DOWN key to go to the next volume
level
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
PROGRAMMING
PART 2 NOVEMBER 2001
LEVEL & GAIN
DISPLAY
TX LEVEL CONTROL
LEVEL 0 → → → → 0
TX LEVEL CONTROL
LEVEL 0 → → → → 1
TX LEVEL CONTROL
LEVEL 1 → → → → 2