Chapter 5 Information Settings and Display
5.4 Utility > show pinned-data

show pinned-data

If certain failure events have occurred when writing data, data cannot be written back to the disk(s)
(volumes) from the cache data area. The data that cannot be written back to the disk is retained in the cache
data area and is called pinned data (PIN).This command displays a list of all the pinned data.
Syntax
show pinned-data
Parameter
No parameters.
Output
# Volume
# No.
Name
#
1 VolumeNumber0001 0x0000000000000000 0x00 0x00 0x00 0x00
A
B
A:
Volume number
B:
Volume name
C:
Logical block address (LBA of volume in which pinned data is retained)
D:
Reason code
E:
Sense key
F:
Additional sense code (Sense code)
G:
Additional sense code qualifier (Sub sense code)
Example(s)
The following example displays a list of all the pinned data:
CLI> show pinned-data
Volume
No.
Name
1 VolumeNumber0001 0x0000000000000000 0x00 0x00 0x00 0x00
1 VolumeNumber0001 0x0000000000000100 0x00 0x00 0x00 0x00
3 Vol3
4 Vol4
4 Vol4
11 Vol11
The following example displays the MLU volumes:
CLI> show pinned-data
Volume
No.
Name
- -
LBA
RC
C
D
LBA
RC
0x0000000000000000 0x00 0x00 0x00 0x00
0x0000000000000000 0x00 0x00 0x00 0x00
0x0000000000001000 0x00 0x00 0x00 0x00
0x0000000000000000 0x00 0x00 0x00 0x00
LBA
RC
-
0x00 0x00 0x00 0x00
680
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
SK
ASC
ASCQ
E
F
G
SK
ASC
ASCQ
SK
ASC
ASCQ
P2X0-1030-09ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents