Page 3
Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system. The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to a Fujitsu (PRIMEQUEST, PRIMERGY, or SPARC Enterprise) or other server.
This chapter describes the components of the ETERNUS DX80 S2/DX90 S2 Disk storage system. ● Chapter 2 Basic Operation This chapter explains how to turn on and off the ETERNUS DX80 S2/DX90 S2 Disk storage system and how to operate the FUNCTION button on the controller enclosure. ● Chapter 3 Setup...
Page 5
ETERNUS DX Disk storage system and/or to CAUTION other users and their property, if the ETERNUS DX80 S2/DX90 S2 Disk storage system is not used properly. This symbol indicates IMPORTANT information for the user to note when IMPORTANT using the ETERNUS DX80 S2/DX90 S2 Disk storage system.
ETERNUS DX80 S2/DX90 S2 Disk storage system: - Make sure to disconnect the power when cleaning. - Be careful that no liquid seeps into the ETERNUS DX80 S2/DX90 S2 Disk storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS DX80 S2/DX90 S2 Disk storage system.
Data Encryption ....................41 Eco-mode ......................42 Data Management .................... 44 3.4.1 RAID Migration .......................... 45 3.4.2 Logical Device Expansion (LDE) ....................46 3.4.3 LUN Concatenation ........................46 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 8
Appendix A Event Notification Message List ...........90 Message Format ....................90 A.1.1 E-mail ............................90 A.1.2 Syslog............................92 A.1.3 SNMP ............................95 A.1.4 Host Sense ..........................99 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 9
Common Terms........................100 A.2.2 Error Messages ........................101 A.2.3 Warning Messages........................116 A.2.4 Informational Messages ......................126 A.2.5 Test Messages ........................131 A.2.6 Sense Codes ........................... 132 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 10
Positions of 3.5" drive slots......................54 Figure 5.3 Installation diagram for a host interface adapter (single-controller type)........76 Figure 5.4 Installation diagram for host interface adapters (dual-controller type)........77 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 11
Table 6.1 Time for volume formatting (disk) ....................79 Table 6.2 Rebuild process time (disk) ....................... 80 Table 6.3 Copyback process time (disk) ....................80 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
3.5" type Operation panel 3.5" disk or 3.5" Solid State Drive (SSD) Flange cover Flange cover Figure 1.2 Front view of a 3.5" type controller enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
■ Dual-controller type Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) Figure 1.4 Rear view of a controller enclosure (dual-controller type) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Without a flange cover POWER LED READY LED FAULT LED FUNCTION button MAINT/ID LED CACHE LED Power switch Figure 1.6 Operation panel (3.5" type controller enclosure) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
There is data in the ETERNUS DX Disk storage (green) system cache memory. ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.7 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The drive is in error status. (orange) • In response to commands from Microsoft Virtual Disk Service (VDS) or ETERNUS CLI, the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
• LAN (RMT) port, LAN (MNT) port These ports are RJ-45 connectors for LAN cables. LAN (RMT) port is not used in the EMEA&I region. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
A host interface adapter is a board that has interface ports to connect a controller to the server. There are five types of host interfaces: FC, iSCSI 10Gbit/s, FCoE, iSCSI 1Gbit/s, and SAS. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
If a power outage is detected, data in the cache memory is saved to the non-volatile memory in the controller using the SCU. The saved data is retained in the non- volatile memory indefinitely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
AC power is supplied to the other power supply unit. The power supply unit or the (off) (orange) (orange) (orange) fan in the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
3.5" disk or 3.5" Solid State Drive (SSD) DE-ID (drive enclosure number) display panel Flange cover Flange cover Figure 1.17 Front view of a 3.5" type drive enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
This section describes LEDs, a DE-ID (drive enclosure number) display panel, and drives of the front of the drive enclosure. ■ DE-ID (drive enclosure number) display panel The DE-ID (drive enclosure number) of the drive enclosure is displayed. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The drive enclosure is in error status. (orange) POWER The drive enclosure is operating normally. (green) ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.21 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The drive is in error status. (orange) • In response to commands from Microsoft Virtual Disk Service (VDS), the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The link between the DI (OUT) port and the (green) destination port has been established. DI (IN) LINKUP The link between the DI (IN) port and the source (green) port has been established. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The power supply unit or the fan in (off) (orange) (orange) (orange) the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
(AC input cable). • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
This turns on and off the power distribution unit. • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
This turns on and off the power distribution unit. • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
For 1U power distribution unit Main line switch Figure 2.1 ON position (marked "|") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
For 1U power distribution unit Main line switch Figure 2.3 OFF position (marked "O") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
OFF (marked "O"), turn it back to ON (marked "I") after the POWER LED of the power supply unit has turned off completely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
AC power is supplied to a power supply unit. The POWER LED on the power supply unit blinks green. The fan revolves at high speed for about 30 seconds. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
Do not turn the main line switches of the power distribution units and the PSU switches on the ETERNUS DX Disk storage system to the OFF posi- tion. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 36
Press the Power switch of the controller enclosure. Drive enclosure Power switch Drive enclosure Controller enclosure The POWER LEDs on the controller enclosure and the drive enclosures are turned on. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Press and hold the Power switch of the controller enclosure for four seconds or more. Drive enclosure Power switch Drive enclosure Controller enclosure The READY LED of the controller enclosure is turned off. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Restoring the factory default settings (network environment settings and firewall settings) of the LAN ports The following procedure explains how to use the FUNCTION button. Procedure Remove the flange cover of the controller enclosure. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 39
Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX Disk storage system is not in maintenance status when the MAINT/ID LED is off. Attach the flange cover. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
To use the Thin Provisioning function, register the Thin Provisioning license in the ETERNUS DX Disk storage system and set up the Thin Provisioning function. For details on the usage and overview of Thin Provisioning, refer to "ETERNUS DX80 S2/DX90 S2 Disk storage system Overview".
Thin Provisioning Volumes (TPVs) cannot be encrypted individually. Rather, the encryption status of TPVs depends on that of the TPP to which the TPVs belong. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
"Host I/O Monitoring Interval". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 43
Network Time Protocol (NTP) server in the date and time setting in ETERNUS Web GUI or ETERNUS CLI to set automatic adjustment of the date and time. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
Migrating to a RAID group with a different RAID level changes the RAID level of volumes. This is used to convert the RAID level of all the volumes belonging to a given RAID group. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
If the power is turned off or an electrical power outage occurs during RAID Migration, the process will simply continue when the power is restored. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The ability to concatenate widely distributed free areas in the ETERNUS DX Disk storage system allows efficient use of the drive capacity. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
Page 47
When a volume that is using ETERNUS SF AdvancedCopy Manager to run backups is expanded via LUN Concatenation, the volume will need to be registered with ETERNUS SF AdvancedCopy Manager again. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
ETERNUS DX Disk storage system of the previous Master CM’s are taken over by the new Master CM. Figure 4.1 LAN control (switching of the Master CM) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Event notification and status display for the ETERNUS DX Disk storage system can be performed by ETERNUS CLI. When ETERNUS CLI is used, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The status of the ETERNUS DX Disk storage system and the usage status of RAID groups, TPPs, and SDPs can be checked in the Overview screen of ETERNUS Web GUI. Figure 4.3 ETERNUS Web GUI screen ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The methods that can be used to notify an event are "e-mail", "SNMP Trap", "syslog", "remote support", and "host sense". Note that REMCS is not available in the EMEA&I region. For the procedure on setting event notification, refer to "ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-".
(host) center REMCS/SNMP (*1) ETERNUS DX Disk storage system *1: SNMP for the EMEA&I region and REMCS for all other regions Figure 4.4 Event notification ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Do not uninstall or move a drive that is already installed. Contact your sales representative or maintenance engineer if a drive needs to be uninstalled or moved. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
To avoid this, allow the packed drive sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 56
Do not stack drives or stand drives on end. • Do not apply external force to the interface connectors. • Do not knock or drop the drives on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Push into the tab of the dummy drive unit and pull it straight out of the drive slot. Dummy drive unit The removed dummy drive unit should be retained for future use. IMPORTANT ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 58
Check that the newly installed drive's DRIVE READY LED lights up green. Repeat Step 3 Step 4 for each additional drive. Remove the wrist strap. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 59
The removed dummy drive unit should be retained for future use. IMPORTANT Install the new drive. Press the catch on the drive lock lever to unlock it. Catch Lock lever ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 60
Set up RAID groups, volumes, hot spares, and Host Affinity settings on the new drives, as required. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
At time of purchase, the installable drive enclosure model may be different from those described. To find the web-site to check the latest version of this manual, refer to "Read Me First". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
Do not handle the drive enclosure roughly or subject it to physical shocks when laying it down. • Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The M5 centering screws should be inserted in the 1st and 6th holes above the base line of the controller enclosure. 2U rack rail M5 Centering screws (10mm) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 64
(M5 cage nut) (M5 cage nut) 1st position 1st position (M5 pan head screw) (M5 pan head screw) Base line of drive enclosure Rack rails ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 66
Failure to do so may cause injury. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 67
Use two M5 screws to fasten it in the rack. ■ For regions other than EMEA&I Use four M5 screws to fasten it in the rack. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 68
The DE_No. labels are supplied with the ETERNUS DX Disk storage system. Attach the flange cover that is provided with the ETERNUS DX Disk storage sys- tem. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 69
3.5" type 2.5" type drive enclosure drive enclosure Bracket Thumb screw Repeat this procedure to install more drive enclosures in the rack. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The [Add Drive Enclosure] screen appears. Check the DE-ID (drive enclosure number) for the drive enclosure that is to be added in "Target Drive Enclosure", and click the [Next] button. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 71
The following figures show the connection paths for QSFP cables when drive enclosure 1 is added. • For a single-controller type DI (IN) port Drive enclosure 1 (Added drive enclosure) Controller enclosure DI (OUT) port ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 72
When connecting QSFP cables, check the connector orientation and then firmly push it all the way in. When disconnecting QSFP cables, use the pull-tab to extract the connector. Pull-tab ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 73
The following figure shows an example of attaching destination labels on the QSFP cables that connect the controller enclosure to drive enclosure 1. Drive enclosure 1 (Added drive enclosure) Controller enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 74
The power cords must be connected to the inlets of both power supply units. Connect the power cord plugs to the inlets of the power supply units. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 75
Step Install the drives. For details on drive installation, refer to "5.1.4 Additional Drive Installation Procedure" (page 57). Remove the wrist strap. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Contact your sales representative or maintenance engineer if a host interface needs to be uninstalled or moved. • Contact your maintenance engineer when a host interface adapter is installed in the channel adapter (CA#1) of the ETERNUS DX80 S2/ DX90 S2. 5.3.1 Installation Rules for Host Interfaces This section explains the installation rules for host interfaces.
To avoid this, allow the packed host interface adapter sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 78
• Do not put anything on the host interface adapter. • Do not knock or drop the host interface adapter on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
The value shows the copyback process time when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
If a possible error that may occur is detected or an error occurs when remote support service is used, the contents of events are automatically sent to the remote support center and notified to the user. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Has there been a recent main power failure? If the Power Resume function is enabled, the ETERNUS DX Disk storage system turns on automatically after the power is restored. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 83
2 Connect the QSFP cable while the drive enclosure is on. 3 Press the controller enclosure’s Power switch to turn on the ETERNUS DX Disk storage system. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 84
In the details screen for each component, check the detailed information for each component with a and contact your maintenance engineer. When checking the general status via ETERNUS CLI, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 85
IMPORTANT for all of the LAN ports are initialized after the following procedure is per- formed. Procedure Remove the flange cover of the controller enclosure. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 86
• To use the SNMP Manager, enable the SNMP connection. If not, the ETERNUS DX Disk storage system does not respond to SNMP access. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 87
I/Os are issued for the appropriate number. For details on the number of command queues, refer to "ETERNUS DX Disk storage systems User's Guide -Server Connection-". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
ETERNUS CLI ("show enclosure-status" command) CLI> show enclosure-status Enclosure View Name [ETERNUS DX90 S2] Model Upgrade Status [Not Possible] Model name Model Name [ETxxxxxx] Serial Number [xxxxxxxxxx] Serial number ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 89
Disk storage system, obtain the required log/dump information using the log/dump collection function of ETERNUS Web GUI. Refer to "ETERNUS Web GUI User’s Guide" for how to obtain this information. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
The Severity of the event is displayed. One of the following items is displayed for the message: Error: indicates an error Warning: indicates a warning Information: indicates that information is provided Test: indicates a test mail ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 91
The year is display with four digits. The detailed information of the event is displayed. For multiple process results, each process result is displayed on a separate line. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
6: Informational For the "RFC3164" format, the HEADER part follows the PRI part. For the "RFC5424" format, "1" and then a blank follow the PRI part. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 93
ETERNUS DX Disk storage system is output in the following format: xxx.xxx.xxx.xxx The IPv4 address is output based on the "IETF STD13, RFC 1035" specification. A blank follows this item. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 94
For multiple process results, each process result is enclosed by brackets. Refer to "A.2 Message List" (page 100) for details. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Trap No. 5 returns to normal status. fjdarye100SensorStatusChangeToNormal This Trap is sent to notify that an event notified by Trap No. 6 returns to normal status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 96
[2]:snmpTrapOID coldStart The operation time of 1.3.6.1.6.3.1.1.5.1 the SNMP Agent (centiseconds) The operation time is authenticationFailure 1.3.6.1.6.3.1.1.5.5 reset when the SNMP Agent starts or restarts. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 97
TRAP No. Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of Information [1]:fjdaryTrapItemId SensorStatus alarm cancel Information [2]:fjdarySspMachineId ChangeTo for TRAP No. Information Normal [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 98
Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of 1.3.6.1.4.1.211.4.1.1. Information [1]:fjdaryTrapItemId SensorStatus alarm cancel for 126.1.100.0.26 Information [2]:fjdarySspMachineId ChangeToNormal TRAP No. 6 Information [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
ETERNUS Web GUI or ETERNUS CLI. For details on the sense code that is notified to the server, refer to "A.2.6 Sense Codes" (page 132). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Meaning Hot spares Thin Provisioning Volume(s) Thin Provisioning Pool SMART Self-Monitoring Analysis and Reporting Technology Firmware Hard Disk Drive Solid State Drive Direct Memory Access ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 102
CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) v: EXP number (0) p: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 103
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 104
CA type m: CM number (0 – 1) P: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version oo...: Additional information ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 105
Port number (0 – 1) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 106
Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 107
Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 108
Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 109
Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 110
Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 111
Error uu: DE-ID ("00" for a controller enclosure) Severity Level in the event notifica- tion setting. They are not notified during mainte- nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 112
REC HALT 0 (Path error) • REC HALT 1 (High load) • REC HALT 2 (Error) These mes- sages are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 113
CPU number in CM enabled for Error Severity Level in the event notifi- cation setting. They are not noti- fied during main- tenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 114
System Disk) The device is in Not Ready status. Configuration information is restored using the backup area due to the replacement of a CM (including BUD). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 115
M E8050xxx E8050xxx TPP#xxx was all allocated tenance Usage status of the Thin Provisioning Pool is changed: operations. Warning to Caution xxx: TPP number (hexadecimal) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 117
EXP number (0) p: Port number (0) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 118
S: CA slot number (0 – 1) V: Device number (0 – 1) zz: CA type m: CM number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 119
CE intake temperature error (Warning) is enabled for detected. Warning Level in the event notification setting. They are not notified during mainte- nance opera- tions. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 120
Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 121
Disk speed cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 122
Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 123
Disk capacity cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 124
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 125
PSU error is detected. SS: Component subtype uu: DE-ID ("00" for a controller enclosure) n: PSU number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
I 01000020 User &a Logged out from &b (&c) — Logged out from the device. &a: User name &b: IP address &c: GUI or CLI ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 127
&b: Slot number setting. &c: Type (Global or Dedicated) &d: RAID group number (only for Dedicated Hot Spares) &e: RAID group name (only for Dedicated Hot Spares) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 128
Snap Data Pool (encrypted) usage rate exceeds the threshold (Level1) $a% and reaches $b%. $a: Threshold of Snap Data Pool $b: Usage rate of Snap Data Pool ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 129
The trial license (local copy) has expired I 00000016 The trial license(Remote Copy) has expired. Detail information is not displayed. The trial license (remote copy) has expired. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 130
CE or DE. the event notifica- tion setting. This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Slot#0 in CE is in Fault status. A drive is not actually disconnected when a test Trap is notified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED...
"Sensor (Temperature) Error" or "Parts error" is enabled for Error Severity Level in the event notification setting. They are not notified during mainte- nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 133
Error Severity Level in the Rebuilding to a drive is complete. event notification setting. They are not notified during Copyback starts. maintenance operations. Copyback is complete. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 134
DE port error is detected. Level in the event notification setting. DE QSFP port error is detected. They are not notified during mainte- nance operations. PSU error is detected. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 135
"Sensor (Temperature) warning" is DE intake temperature error is detected. enabled for Warning Level in the event notification setting. They are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2011 FUJITSU LIMITED P3AM-4842-01ENZ0...
Page 136
• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. •...
Need help?
Do you have a question about the Eternus DX80 S2 and is the answer not in the manual?