Chapter 4 Function/System Settings and Display
4.3 Network Management > set network
-slave-link-local-ip
-master-connect-ip
-slave-connect-ip
-netmask
-subnet-prefix-length
Optional. This parameter specifies the link local IP address of the slave IP. If omitted, the
existing setting is not changed. This parameter can only be specified when "v6" is specified for
the "-ip-format" parameter and "disable" is specified for the "-ipv6-set-auto" parameter.
Example: -slave-link-local-ip fe80::9ab0:2d0
Optional. This parameter specifies the connect IP address of the master IP. Global unicast
addresses (including 6to4 addresses) and unique local unicast addresses can be specified for
the connect IP address. If omitted, the existing setting is not changed. This parameter can only
be specified when "v6" is specified for the "-ip-format" parameter and "disable" is specified for
the "-ipv6-set-auto" parameter.
Example: -master-connect-ip 2003:12b:84d::87:3e3
Optional. This parameter specifies the connect IP address of the slave IP. Global unicast
addresses (including 6to4 addresses) and unique local unicast addresses can be specified for
the connect IP address. If omitted, the existing setting is not changed. This parameter can only
be specified when "v6" is specified for the "-ip-format" parameter and "disable" is specified for
the "-ipv6-set-auto" parameter.
Example: -slave-connect-ip 2003:120:84d::7ac:45
Optional. This parameter specifies the subnet mask for the specified Ethernet port. The format
is IPv4 standard notation (a base 256 "d.d.d.d" string) or IPv6 address format. If omitted, the
existing setting is not changed. This parameter can only be specified when "v4" is specified for
the "-ip-format" parameter.
Example: -netmask 255.255.255.0
Optional. Specify a value from 3 to 128. When a global unicast address is specified for the
connect IP address, a value from 3 to 128 can be specified. When a unique local unicast
address is specified for the connect IP address, a value from 7 to 128 can be specified. (When a
6to4 address is used to specify the global unicast address, a value from 48 to 128 can be
specified.) If omitted, the existing setting is not changed. This parameter can only be specified
when "v6" is specified for the "-ip-format" parameter and "disable" is specified for the "-ipv6-
set-auto" parameter. To delete the prefix length, set "0".
Example: -subnet-prefix-length 64