Huawei EchoLife HG8110 Service Manual page 167

Gpon terminal
Table of Contents

Advertisement

EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
Issue 02 (2011-12-08)
c.
Click Apply to apply the configuration.
4.
Configure parameters of the H.248-based voice users.
a.
In the navigation tree, choose Voice > VoIP User Configuration.
b.
In the right pane, configure the parameters of voice user 1 as follows:
– Line Name: A0
– Associated POTS: 1 (binding port TEL1 on the ONT)
– Select Enable Line Name to enable the voice user configuration.
c.
Click Apply to apply the configuration.
d.
In the right pane, click New to add voice user 2, and configure the parameters of
voice user 2 as follows:
– Line Name: A1
– Associated POTS: 2 (binding port TEL2 on the ONT)
– Select Enable Line Name to enable the voice user configuration.
e.
Click Apply to apply the configuration.
NOTE
l The terminal IDs A0 and A1 must be consistent with the corresponding configuration on the
MGC.
l If Associated POTS is 1, port TEL1 on the ONT is bound. If Associated POTS is 2, port TEL2
on the ONT is bound.
5.
Save the configuration.
In the navigation tree, choose System Tools > Configuration File. In the right pane,
click Save Configuration to save the configuration.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Configuration
159

Hide quick links:

Advertisement

Table of Contents
loading