Thresholdcrossingalertopticalreceivepowertoolow; Thresholdcrossingalertopticaltransmitpowertoohigh - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Trouble Clearing

thresholdCrossingAlertOpticalReceivePowerTooLow

Entity Type
EQPT

thresholdCrossingAlertOpticalTransmitPowerTooHigh

Entity Type
EQPT
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical receive power is too low.
Service
Severity
Direction
Affected
warning
non–service-
receive
affecting
Probable Cause
Optical receive power is too high.
Location
Description
NEND
The optical receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1...4
■ For BDL1-3B11: LCN1...4
Suggested Corrective Action
1. Verify that the appropriate transmitter is installed at
the far end.
2. Verify that the transmit output level is within
specifications at the far end.
3. Replace the transmitter at the far end if the level is too
low.
4. Clean the fiber connections in the path.
Location
Description
NEND
The optical receive power level is above the
threshold on one of the following ports:
■ For BDL1-3R11:
• E-SC-E1
• F-SC-E1
• LCN1...4
■ For BDL1-3B11: LCN1...4
Suggested Corrective Action
1. Verify that the transmitter output level is within
specifications.
2. Replace the blade if necessary.
Fujitsu and Fujitsu Customer Use Only
336