Databaselockedsoftwareupgradeinprogress; Databaseversionmismatch; Equipmentcurrexceededfeed - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Trouble Clearing

databaseLockedSoftwareUpgradeInProgress

Entity Type
COM

databaseVersionMismatch

Entity Type
COM

equipmentCurrExceededFeed

Entity Type
BDL1-3B11, BDL1-3R11
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
The database is locked due to a software
upgrade in progress.
Service
Severity
Direction
Affected
major
non–service-
n/a
affecting
Probable Cause
The database system of a tributary blade
does not match the database system read
from the Main blade.
Service
Severity
Direction
Affected
critical
non–service-
n/a
affecting
Probable Cause
Current drawn is greater than 80 percent of
unit fuse feed rating.
Location
Description
NEND
Database System Locked; Software Upgrade
In Progress
Suggested Corrective Action
No action is required. The condition clears when the
software upgrade completes.
Location
Description
NEND
Database Version Mismatch
Suggested Corrective Action
1. If executing a new turn-up, perform a WARM reset on
the tributary blade.
2. If the condition does not clear or if the tributary blade
is carrying traffic, call Fujitsu for technical assistance at
1-800-USE-FTAC (1-800-873-3822).
Location
Description
NEND
The current drawn is greater than 80
percent of the fuse rating.
Suggested Corrective Action
Increase the rating for the fuse feed.
Fujitsu and Fujitsu Customer Use Only
301

Advertisement

Table of Contents
loading

Table of Contents