System Maintenance
Trouble Clearing
equipmentLedOn
Entity Type
PIL1-3PS2
BDL1-3M21, BDL1-3R11,
BDL1-3B11
equipmentMiscabledConnection
Entity Type
1GEX, 1GEBT
equipmentMismatchAttributes
Entity Type
AC00-F011
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
An LED on the PIU has been intentionally
activated.
warning
non–service-
n/a
affecting
Probable Cause
An LED on the blade has been intentionally
activated.
Service
Severity
Direction
Affected
major
non–service-
n/a
affecting
Probable Cause
The interblade communication cables are
not installed correctly.
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
■ A Fan unit is mismounted.
■ A Fan unit slot is not provisioned
correctly.
Location
Description
NEND
Equipment Common Visual LED Activated:
TYPE = <unit type>
Suggested Corrective Action
Deactivate the LED.
NEND
Equipment Common Visual LED Activated:
TYPE = <unit type>
Suggested Corrective Action
Deactivate the LED.
Location
Description
NEND
Interblade communication Miscabled
Connection: TYPE = <unit type>
Suggested Corrective Action
Perform eqpt-reset with reset ADOPTSHELF.
> request eqpt-reset shelf-id 1 reset
ADOPTSHELF
Location
Description
NEND
Mismatch of Equipment and Attributes:
TYPE=<unit type> and the admin-status is
down
Suggested Corrective Action
1. Remove and remount the Fan unit.
2. Correct the Fan unit slot provisioning.
Fujitsu and Fujitsu Customer Use Only