System Maintenance
Trouble Clearing

postBlockSpanAdjustmentInProgress

Entity Type
oms

powerOutOfSpecificationHigh

Entity Type
Subport (Edge)
Subport (Edge)
Subport (Client)
Port (Edge)
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
warning
non–service-
n/a
affecting
Probable Cause
Post block span adjustment is in progress.
Service
Severity
Direction
Affected
critical
service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
edge subport is too high.
critical
service-
receive
affecting
Probable Cause
The optical power on the indicated receive
edge subport is too high.
critical
service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
client subport is too high.
critical
service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
edge port is too high.
Location
Description
NEND
Post Block Span Adjustment in Progress:
TYPE = <unit type>
Suggested Corrective Action
No action is required. This condition automatically clears
when the post block span adjustment completes.
Location
Description
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated subport.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated subport.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated subport.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated port.