Set Up Main Blade (Initial) - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

Initial System Turn Up

Set Up Main Blade (Initial)

5.2
Set Up Main Blade (Initial)
Warning: After the blade is powered up, power down within 15 minutes causes database corruption,
which leads to blade start-up failure and requires a return to factory for reprogramming.
Step 1
Apply power to the Main blade.
Step 2
Log on the blade using the LMP as described in
Step 3
Retrieve the alarms.
Command:
> show alarms alarm-list
Step 4
Check if the shelfProvisioningMode alarm is present.
If YES:
Continue with next step.
If NO:
This procedure is complete.
Step 5
Execute the Main blade setup.
Command:
> request set-shelfmode shelfid <shelf-id˃ shelfrole <shelf-role˃
Table 43
Input Parameter
Parameter
shelf-id
shelf-role
Command Example:
> request set-shelfmode shelfid 1 shelfrole MAIN
Step 6
When the question "Really want to do this?" appears, enter "yes".
·
Release 19.1.1
Issue 1.1, May 2021
Log
On.
Value
<1>
<MAIN>
Description
Shelf value for the blade
Name of shelf role
Fujitsu and Fujitsu Customer Use Only
162

Advertisement

Table of Contents
loading