Rack latches replacement

Follow instructions in this section to remove and install the rack latches.
Note: Depending on the model, the left rack latch might be assembled with a VGA connector and the right
rack latch might be assembled with the front I/O module.
"Remove the rack latches" on page 122
"Install the rack latches" on page 125

Remove the rack latches

Follow instructions in this section to remove the rack latches.
About this task
Attention:
• Read
"Installation Guidelines" on page 39
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Watch the procedure
A video of this procedure is available at YouTube:
DR4X1YAcp9wFKhwj_tLQ5Y
Procedure
Step 1.
Make preparation for the task.
a.
If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
b.
If the server is installed with the security bezel, remove it first. See
on page
137.
c.
Remove the top cover. See
d.
Remove the air baffle. See
Step 2.
Disconnect the VGA cable, the front I/O module cable, or both cables from the system board
assembly.
Notes:
• If you need to disconnect cables from the system board assembly, disengage all latches or
release tabs on cable connectors first. Failing to release the tab before removing the cables will
damage the cable sockets on the system board assembly. Any damage to the cable sockets
might require replacing the processor board or system I/O board.
• The connectors on your system board assembly might look different from those in the
illustration, but the removal procedure is the same.
1. Press the release tab to release the connector.
ThinkSystem SR665 V3 User Guide
122
and
"Safety inspection checklist" on page 40
48.
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
.
"Remove the top cover" on page
"Remove the air baffle" on page
"Remove the server from rack" on page
"Remove the security bezel"
161.
57.
to ensure that you
49.

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9a7d9b

Table of Contents