10. Download and install the latest device drivers:
servers/thinksystem/sr665v3/7d9a/downloads/driver-list/
11. Update the system and device firmware. See
Note: (Lenovo trained technician only) If you have replaced the firmware and RoT security module,
update the firmware to the specific version supported by the server. See
RoT security module
Update the Vital Product Data (VPD)
Use this topic to update the Vital Product Data (VPD).
• (Required) Machine type
• (Required) Serial number
• (Optional) Asset tag
• (Optional) UUID
Recommended tools:
• Lenovo XClarity Provisioning Manager
• Lenovo XClarity Essentials OneCLI commands
Using Lenovo XClarity Provisioning Manager
Steps:
1. Start the server and press the key according to the on-screen instructions. The Lenovo XClarity
Provisioning Manager interface is displayed by default.
2. Choose System Summary. The "System Summary" tab page is displayed.
3. Click Update VPD, then, follow on-screen instructions to update the VPD.
Using Lenovo XClarity Essentials OneCLI commands
• Updating machine type
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
• Updating serial number
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
• Updating asset tag
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
• Updating UUID
onecli config createuuid SYSTEM_PROD_DATA.SysInfoUUID [access_method]
Variable
<m/t_model>
<s/n>
ThinkSystem SR665 V3 User Guide
154
.
Description
The server machine type and model number.
Type xxxxyyy, where xxxx is the machine type and yyy is the server model number.
The serial number on the server.
Type zzzzzzz, where zzzzzzz is the serial number.
https://datacentersupport.lenovo.com/tw/en/products/
.
"Update the firmware" on page
189.
Tip for replacing a firmware and