Advertisement

Install the 4 x 2.5" drive backplane and drive cage
Follow instructions in this section to install the rear 2.5-inch 4-bay drive backplane and drive cage.
About this task
Attention:
• Read
"Installation Guidelines" on page 39
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• The rear drive cage is supported on some server models with thermal requirements. See
on page 47
to ensure that the server is under permitted ambient temperature and the correct heat sink
and system fans are used. If needed, replace your heat sink or system fan first.
"Processor and heat sink replacement (trained technician only)" on page 112
"System fan replacement" on page 155
Watch the procedure
A video of this procedure is available at YouTube:
DR4X1YAcp9wFKhwj_tLQ5Y
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
Install the drive backplane into the rear drive cage.
Figure 98. Installing the 4 x 2.5-inch rear drive backplane
a.
Align the bottom of the backplane with the studs at the bottom of the drive cage.
ThinkSystem SR665 V3 User Guide
136
and
"Safety inspection checklist" on page 40