Memory Problems - Lenovo ThinkSystem SR665 V3 User Manual

Hide thumbs Also See for ThinkSystem SR665 V3:
Table of Contents

Advertisement

Memory problems

See this section to resolve issues related to memory.
Common memory problems
"Displayed system memory is less than installed physical memory" on page 220
"Invalid memory population detected" on page 220
"DIMM PFA issue" on page 220
Displayed system memory is less than installed physical memory
Complete the following procedure to solve the problem.
Note: Each time you install or remove a memory module, you must disconnect the server from the power
source.
1. See
"Memory module installation rules and order" on page 44
module population sequence is supported and you have installed the correct type of memory module.
2. Check whether any DIMM error LED is lit on the processor board and whether any memory module is
not displayed in Setup Utility. If yes, check the customer/L1 actions by following the error event
triggered in XCC or UEFI.
3. If the problem persists, replace the failing memory module with one that functions well.
• If the new memory module still functions well, it indicates that the original memory module is
damaged. In this case, replace the memory module with a good one.
• If the new memory module cannot function well, it indicates that the memory slot is damaged. In this
case, replace the processor board (trained technician only).
• There are few cases in which the memory error is relative to processors. Replace the affected
processors if the above actions does not help on customer's situation (trained technician only).
4. Run the memory module diagnostics. When you start a server and press the key according to the on-
screen instructions, the Lenovo XClarity Provisioning Manager interface is displayed by default. From
the Diagnostic page, click Run Diagnostic ➙ Memory Test ➙ Advanced Memory Test. If any memory
module fails the test, repeat steps 2 and 3.
Invalid memory population detected
If this warning message appears, complete the following steps:
Invalid memory population (unsupported DIMM population) detected. Please verify memory configuration is valid.
1. See
"Memory module installation rules and order" on page 44
population sequence is supported.
2. If the present sequence is indeed supported, see if any of the modules is displayed as "disabled" in
Setup Utility.
3. Reseat the module that is displayed as "disabled," and reboot the system.
4. If the problem persists, replace the memory module.
DIMM PFA issue
1. Update the UEFI and XCC firmware to the latest version.
2. Reseat the failing memory modules.
3. Swap processors and make sure that there are no damages to processor socket pins.
4. (Train service only) Ensure there is no abnormal material in any memory module slot.
ThinkSystem SR665 V3 User Guide
220
to make sure that the present memory
to make sure the present memory module

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9a7d9b

Table of Contents