5.3.6 Installation of Card-sized I/O

(1) Installation direction
The card-sized I/O installation direction is shown below. Install the card-sized I/O with the
installation 1 or installation 2 direction.
Top
Installation 1
Bottom
(2) Installation spacing
The card-sized I/O installation spacing must be 15mm or more. Refer to Appendix 1 (card-sized I/O
outline drawing) for the installation example.
CHAPTER 5 CONNECTION OF I/O INTERFACE
5.3 Connection of Card-sized I/O
Top
Bottom
Installation 2
(Note) If the card-sized I/O is
62
Top
Bottom
installed horizontally, the heat
will build up, so do not install
the card as shown on the left.