Mitsubishi Electric MELDAS 600 Series Connection Manual page 76

Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

(4) Scan output (CF35)
An example of the scan output circuit manufactured by the machine manufacturer is shown below.
Refer to section 2. (2) Pin assignment for the connector pin assignments.
CF35
LC3A
LC2A
LC1A
LC0A
LDOA∗
LD1A∗
LD2A∗
LD3A∗
LD4A∗
LD5A∗
LD6A∗
LD7A∗
<Example of circuit manufactured by
machine manufacturer>
Output circuit
The scan output changes the common signals as shown below. The LED lights only when the data
is output and the common signal is High. The common signal changes four signals in order. It lights
only for 1.46ms once every 5.84ms. The scan output is a 5V system.
LC3A
LC2A
LC1A
LC0A
1.46ms
5.84ms
CHAPTER 5 CONNECTION OF I/O INTERFACE
5.4 Scan I/O
Y00
Y01
Y02
Y03
Y04
Y05
Y06
Y07
Y08
Y09
Y0A
Y0B
Y0C
Y0D
Y0E
Y0F
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
〈HR347/357〉
5V
CF35
LCnA/B
330Ω
LDnA/B∗
CF35
LC3B
LC2B
LC1B
LC0B
LDOB∗
LD1B∗
LD2B∗
LD3B∗
LD4B∗
LD5B∗
LD6B∗
LD7B∗
<Example of circuit manufactured by
<Manufactured by machine manufacturer>
LC3B
LC2B
LC1B
LC0B
1.46ms
5.84ms
70
Y20
Y21
Y22
Y23
Y24
Y25
Y26
Y27
Y28
Y29
Y2A
Y2B
Y2C
Y2D
Y2E
Y2F
Y30
Y31
Y32
Y33
Y34
Y35
Y36
Y37
Y38
Y39
Y3A
Y3B
Y3C
Y3D
Y3E
Y3F
machine manufacturer>

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas m615Meldas m635Meldas m610Meldas m630

Table of Contents