3.3.3 Connecting Spark Killers

The generated noise must be removed when the coil/contact operates.
As a measure, connect a spark killer in parallel with the coil/contact.
The CR compound element is useful for eliminating noise generated by magnetic induction.
CHAPTER 3 INSTALLATION
3.3 Noise Countermeasures
Connector
name
CF10
)
ENC2
HANDLE
)
CF21
CF22
K/B
MOUSE
CF10
)
SV1
)
SV2
)
ENC1
SKP
RIO1
RIO2
Contact
E
Spark killer
C: 0.033 ~ 0.1µF
R: 10 ~ 120Ω