6.7 Outline of Analog Signal Input Circuit

The analog signal output circuit can be used only for the FCUA-DX140/DX141.
Input circuit
Input conditions
Max. input rating
Resolution
Precision
AD input sampling time
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.7 Outline of Analog Signal Input Circuit
150Ω
A0
A0∗
±15V
10V/2000 (5mV)
Within ±25mV
14.2ms (A10)/42.6ms (AI1~3)
ADC
80