Coi Initial Data Setup - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-10 : COI Initial Data Setup to define the various basic timers for
each COI trunk port.
Input Data
Item
No.
01
02
03
04
05
06
Electra Elite IPK II Programming Manual
Trunk No.
Item
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Use this
Program to select either Pattern A or pattern
B.
Prepause Time Selection
Specifies the loop open time for a hookflash
signal sent to the CO or PBX when the
Recall key on a multiline terminal is
pressed. A Single Line Telephone (SLT)
generates a hookflash to the CO or PBX
line when a SLT hookflash is assigned.
Incoming Signal Detect Time Selection
Specifies the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
Disconnect Recognition Time Selection
Specifies the minimum time before a
disconnected circuit can be accessed
again.
Auto Release Signal Detection Time
Specifies the signal detection time for
release of a CO/PBX line after a disconnect
signal is received from the distant CO or
PBX.
Pause Time Selection

81-10 : COI Initial Data Setup

1~ 200
Input Data
0 = Pattern A
(Pattern A: 10pps - 650 ms,
20pps - 500 ms)
1 = Pattern B
(Pattern B: 10pps - 800 ms,
20pps - 800 ms)
1~13
(1~13 seconds)
(0 = No Setting)
0~15
(50~800 ms)
1~15
(100 ms~1.5 seconds)
(0 = No Setting)
1~14
(50~700 ms)
15 =
(0 = No Setting)
1~15
(500~7500 ms)
Document Revision 1
Default
1
9
(600 ms)
3
(200 ms)
3
(300 ms)
7
(350 ms)
3
(200 ms)
2 - 495

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents