25-03 : VRS/DISA Transfer Ring Group With Incorrect Dialing

Level:
IN
Description
Use Program 25-03 : VRS/DISA Transfer Ring Group With Incorrect Dialing to set
what happens to a call when the DISA or Automated Attendant caller dials incorrectly
or waits too long to dial. The call can either disconnect (0) or Transfer to an alternate
destination (a ring group or voice mail). When setting the DISA and DID Operating
Mode, make an entry for each Night Service mode.
Input Data
Feature Cross Reference
J
Electra Elite IPK II Programming Manual
Trunk Port Number
Item
Day/Night
No.
Mode
01
1~8
Conditions
None
Direct Inward System Access (DISA)
Program 25 : DID/DISA Setup
Incoming Group Number
0 (Disconnect)
1~8 or 1~100 (Incoming Group)
101 (DSPII-U10 Internal Voice
Mail on Compact Flash)
102 (In-Skin/External Voice Mail)
103 (Centralized Voice Mail)