Dial Analysis Extension Table - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Level:
IN
Description
When Program 44-02-02 is set to type "3", use
Extension Table
the analyzed digits must be more than 8 digits. If the received digits do not match the
digits set in tables 1~250, table number 252 is used refer to the next Extension Table
Area (1~4) to be searched. If the received digits are not identified in tables 1~250, the
F-Route selection table number defined in table 251 is used.

Input Data
Dial Analysis Table Number : 1~250
Item
No.
01
02
2 - 396
Program 44 : ARS/F-Route Setup

44-03 : Dial Analysis Extension Table

to set the dial extension analysis table. These tables are used when
The item numbers indicated below are different when using PCPro/WebPro due to the
window layout of the applications. Refer to the program within the PCPro/WebPro
application to determine the correct item number.
Extension Table Area Number
Dial Analysis Table Number
Item
Dial
ARS/F-Route Select
Table Number
Program 44-03 : Dial Analysis
Input Data
Up to 24 digits
Digits = 1~9, 0,
, #, @
,
(Press Line Key 1 for wild character @)
0~500 (ARS/F-Route Table Number)
With Program 44-01 set to "0", Program 44-05
is then checked.
With Program 44-01 set to "1", Program 44-04
is then checked.
Program 44 : ARS/F-Route Setup
Electra Elite IPK II
1~4
1~252
Default
No Setting
0

Hide quick links: