Description
Use Program 32-03 : Door Box Basic Setup to select the chime pattern and gain
level for each Door Box. There are six distinctive chime patterns. The chime tones are
defined in Program 80-01.

Input Data
Feature Cross Reference
J
Electra Elite IPK II Programming Manual
Program 32 : Door Box and Sensor Setup
The Door Box feature is referred to as "Door Phone" when programming via Web Pro
and using a Multiline Terminal.
Door Box Number
Item
Item
No.
01
Chime Pattern
02
CODEC Transmit Gain Setup
(PGD to Door Box)
03
CODEC Receive Gain Setup
(Door Box to PGD)
Conditions
None
Door Box

32-03 : Door Box Basic Setup

Input Data
0
= None
1
= Door Box Ring 1
2
= Door Box Ring 2
3
= Door Box Ring 3
4
= Door Box Ring 4
5
= Door Box Ring 5
6
= Door Box Ring 6
1~63 (-15.5 ~ +15.5dB)
1~63 (-15.5 ~ +15.5dB)
Document Revision 1
1~8
Default
Door Box 1 = 1
Door Box 2 = 2
Door Box 3 = 3
Door Box 4 = 4
Door Box 5 = 5
Door Box 6 = 6
Door Box 7 = 1
Door Box 8 = 1
32
32
2 - 321