Step 5 Install the new fire alarm sounder.
Step 6 Switch on the active and standby power supplies to the fire alarm control panel.
Step 7 Check that the new fire alarm sounder is working properly.
Unlock the fire alarm control panel, and press the ALARM BELL key to trigger the fire alarm
sounder.
----End
Follow-up Procedure
Dispose of the removed fire alarm sounder that is confirmed faulty.

5.4.1.9 Replacing the Emergency Start/Abort Switch

Prerequisites
A spare emergency start/abort switch of the same model is available and
functional.
Impact on the System
The fire extinguishing system stops working during the replacement.
Prerequisites
Tools: Phillips screwdriver, flat-head screwdriver, protective gloves
Material: spare emergency start/abort switch
Document: fire extinguishing device layout diagram (standard)
Skill requirement: fire engineer
Procedure
Step 1 Switch off the active and standby power supplies to the fire alarm control panel.
Step 2 Use a Phillips screwdriver to remove the screws from the emergency start/abort
switch, as shown in
Issue 04 (2021-02-10)
NO TE
NO TE
Before replacing the emergency start/abort switch, inform the related administration
department of the temporary downtime of the fire extinguishing system. After the
replacement, inform the administration department that the system has become
operational.
Figure
Copyright © Huawei Technologies Co., Ltd.
5-46.